Project compliant with:
UNI EN 12193:2019: Class I

REQUIREMENTS

Playing area dimensions

Length [m] 28
Width [m] 15
Grid points Length 13
Grid points Width 7

Values required

Class Emed [lx] Emin/Emed Colour rendering index [Ra] GR
I 500 0.70 70 55

CALCULATION RESULTS

Results

Emed [lux] 565
Emin/Emed 0.81
GR max 42
No. of poles 4
H inst. (m) 8
No. Devices 8
Code GWP2475NS + Power Supply Unit

Isoline

90 lux
100 lux
150 lux
200 lux
250 lux
300 lux
350 lux
400 lux
450 lux
500 lux
600 lux
700 lux

PROPOSED SOLUTION

Smart [PRO] 2.0

SMART [PRO] 2+2 M FLOODLIGHT
GWP2475NS

SM
SM

CORRELATED INSTALLATIONS