Hockey

Project compliant with:
UNI EN 12193:2019: Class II

Hockey

REQUIREMENTS

Size of playing area/total area

Length [m] 91 / 101
Width [m] 55 / 63
Grid points Length 19 / 21
Grid points Width 11 / 13

Values required

Class Emed [lx] Emin/Emed Colour rendering index [Ra] GR
II 300 0.70 60 50

CALCULATION RESULTS

Main area results

Emed [lx] [lux] 331
Emin/Emed 0.74
GR max 32
No. of poles 6
H inst. (m) 20
No. Devices 36
GW Code GWP2475CS
Accessory + Power Supply Unit

Isoline

150 lux
200 lux
250 lux
300 lux
350 lux
400 lux
450 lux
500 lux
600 lux
700 lux
800 lux

PROPOSED SOLUTION

Smart [PRO] 2.0

SMART [PRO] 2.0 2+2M FLOODLIGHT
GWP2475CS

SM
Smart [PRO] 2.0

CORRELATED INSTALLATIONS

separator