Project compliant with:
UNI EN 12193:2019: Class II

REQUIREMENTS

Playing area dimensions

Length [m] 50 - 200
Width [m] 13 - 20
Grid points Length 17 - 40
Grid points Width 44810

Values required

Class Emed [lx] Emin/Emed Colour rendering index [Ra] GR
II 30 0.30 60 50

CALCULATION RESULTS

Results

Emed [lx] [lux] 31
Emin/Emed 0.30
GR max 36
H inst. (m) 13,0
No. of Devices 3
Code GWP2174NS

Isoline

5 lx
10 lx
20 lx
30 lx
50 lx

PROPOSED SOLUTION

CORRELATED INSTALLATIONS