Hockey

Project compliant with:
UNI EN 12193:2019: Class II

Hockey

REQUIREMENTS

Size of playing area/total area

Length [m] 91 / 101
Width [m] 55 / 63
Grid points Length 19 / 21
Grid points Width 11 / 13

Values required

Class Emed [lx] Emin/Emed Colour rendering index [Ra] GR
III 200 0.70 60 55

CALCULATION RESULTS

Main area results

Emed [lx] [lux] 216
Emin/Emed 0.73
GR max 31
No. of poles 6
H inst. (m) 20
No. Devices 24
GW Code GWP2475CS

Isoline

70 lux
80 lux
90 lux
100 lux
150 lux
200 lux
250 lux

PROPOSED SOLUTION

Smart [PRO] 2.0

SMART [PRO] 2.0 2+2M FLOODLIGHT
GWP2475CS

SM
Smart [PRO] 2.0

CORRELATED INSTALLATIONS